ITC-003_Monitoring_To_Safety_SensorSnapshot_Contract

Verify IF_SensorSnapshot interoperability from monitoring to safety path for hazard detection logic.

Execution

Field

Value

Status

pass

Test Type

interface_contract

Last Run At

2026-02-28T18:11:57Z

Last Runner

Dummy_Integration_Run

Preconditions

Monitoring and safety units are active with protection logic armed for hazard criteria evaluation.

Procedure

Inject snapshot variants from monitoring to safety and record hazard evaluation and invalid-data handling responses.

Expected Result

Safety interprets IF_SensorSnapshot contract correctly and uses valid data for hazard logic while handling invalid data safely.

Traceability

Element Type

Referenced Elements

SW Unit Relations

SW Interfaces

SW Sequences

  • SEQ-002_Protection_And_Fault_Propagation

SW Timing Budgets

n/a