UTC-010_Status_Indication_To_LED_Mapping ======================================== Validate ao_status_indication activity mapping from status and fault events to LED command payload. Execution --------- .. list-table:: :header-rows: 1 :widths: 30 70 * - Field - Value * - Status - pass * - Last Run At - 2026-02-28T18:45:00Z * - Last Runner - Dummy_Unit_Run * - Result Summary - pass Preconditions ------------- Status indication context is initialized with normal warning and fault to LED mapping policy Procedure --------- 1) Inject normal status and dispatch. 2) Inject warning status and dispatch. 3) Inject fault event and dispatch. 4) Check emitted LED commands. Expected Result --------------- Generated LED command values are consistent with activity model for each input condition and no undefined pattern is emitted. Traceability ------------ .. list-table:: :header-rows: 1 * - Element Type - Referenced Elements * - SW Units - * :doc:`ao_status_indication ` * - SW State Machines - * ao_status_indication_activity * - Evidence - n/a