UTC-005_Runtime_Supervisor_Readiness_Gates ========================================== Validate runtime supervisor startup readiness gates before entering run lifecycle. Execution --------- .. list-table:: :header-rows: 1 :widths: 30 70 * - Field - Value * - Status - pass * - Last Run At - 2026-02-28T18:45:00Z * - Last Runner - Dummy_Unit_Run * - Result Summary - pass Preconditions ------------- Supervisor initialized and all required readiness events are controllable in test harness. Procedure --------- 1) Dispatch startup without all gates and verify hold. 2) Assert all readiness events. 3) Dispatch transition cycle. 4) Verify run state entry. Expected Result --------------- Run state is reached only after all configured readiness gates are satisfied; state machine behavior matches defined lifecycle. Traceability ------------ .. list-table:: :header-rows: 1 * - Element Type - Referenced Elements * - SW Units - * :doc:`ao_runtime_supervisor ` * - SW State Machines - * ao_runtime_supervisor_state * - Evidence - n/a