ATC-009_Modbus_Config_Write_Invalid_Rejected ============================================ Validate invalid external configuration writes are rejected safely. Execution --------- .. list-table:: :header-rows: 1 :widths: 30 70 * - Field - Value * - Status - pass * - Test Type - functional_acceptance * - Last Run At - 2026-02-28T17:04:15Z * - Last Runner - Baseline_Verification Preconditions ------------- Writable configuration endpoints are enabled and current valid baseline values are recorded. Procedure --------- Attempt invalid writes including out of range and malformed payloads. After each attempt verify rejection response and re-read active configuration values. Expected Result --------------- Invalid writes are rejected with no unintended state mutation and previous valid configuration remains active. Traceability ------------ .. list-table:: :header-rows: 1 * - Element Type - Referenced Elements * - Requirements - * :doc:`REQ-IFC-004 `